This is an epoch-making product for economizing in consumption of energy for boiler heating. We are sole representative exporter. Please feel free to contact us for more details.
Fuel saving, Optimum indoor, Proportional control, Sensing of water temperature, No relation with pressure, Simple control, Long life, Simple installation.
Special Feature
Fuel saving : *Saving of Heating cost: max. 50% ~ min. 20%*Prices of goods, Installation cost, Cost of subsidiary materials: under 50%
Optimum indoor : *Always constant indoor temperature, 100% pleasant Proportional control *Valve controls proportionally by temperature (Shape memory alloy effect)
Sensing of water temperature : *Prompt and accurate temperature control operating by only water temperature
No relation with pressure : *No relation with pressure by Double Port type (solution of differential pressure between inlet and outlet)
Simple control : *Keep indoor temperature by once for all handle control Wireless remote control system (Option)
Long life : *Excellent for foreign materials and scale by perfect secure of water flow way *Minimum trouble by semipermanent temperature control sensor
Simple installation : *Installation of only connection of union due to no weather sensing sensorl *Simple installation by basic tool at home
Specification
Using Fluid |
Hot Water |
Connection Size |
15A, 20A, 25A, 32A |
End Connection |
Inlet : PT Screwed, Outlet : Union Screwed |
Using Temperature |
Max. 100 deg/c |
Using Pressure |
Max. 10 kgf/cm2 |
Hydraulic Test |
15 kgf/cm2 (3 min) |
Material |
Body |
Brass |
Handle |
Plastic |
Up/Down Disc |
Plastic |
Actuator |
Sensing Spring : SMA & STS 304 |
Standard Size
Standard |
A |
B |
W |
D |
E |
H |
15A |
68 |
32 |
100 |
36 |
89 |
125 |
20A |
70 |
34 |
114 |
36 |
89 |
125 |
25A |
80 |
36 |
116 |
36 |
89 |
125 |
32A |
84 |
38 |
122 |
42 |
105 |
147 |
Heating by Radiator
Radiator heating type is dry air condition than bottom heating type and it has demerits of big temperature fluctuation causing by deflection of existing temperature sensor.
In case of temperature controlling by TC VALVE at place of heating by radiator, Remote Controller (Option) has the effect of controlling of indoor temperature evenly and saving of fuel.
Comparison of the Rate of Boiler Operation
Existing Boiler Type |
|
|
|
|
|
|
|
|
|
|
|
70% |
30% |
|
|
|
|
|
|
|
|
|
|
|
|
|
TC VALVE Applied |
|
|
|
|
|
|
|
|
|
|
|
30% |
70% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operation Time |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Suspension Time |
|
|
|
|
|
|
*** PATENT OF GOODS
|
|